IoT Fire Safety Monitoring (ACMS)

Maharashtra Fire Rules 2025

Know your fire pumps work — before the fire officer, or the fire, finds out.

Most fire-fighting systems fail quietly. A pump left in manual mode, a tripped power supply, a riser that has lost pressure, an empty fire tank: none of it shows until the day the system is needed.

That is why Maharashtra now requires an IoT-based Automated Continuous Monitoring System (ACMS) for the fire-fighting systems of buildings covered by section 45 of the Fire Act. Ultrasafe Equipments supplies, installs, integrates and maintains complete ACMS solutions, connected to your hydrant, sprinkler, pump and fire alarm systems.

  • All 20 parameters listed in the 2025 rules, monitored 24×7
  • Real-time SMS, email and app alerts to owners and your maintenance team
  • Works with existing hydrant, sprinkler and alarm systems
  • Form A-1 / B-1 documentation through a Licensed Agency
Get a Free ACMS Readiness Check
What the law says

ACMS is now part of Maharashtra's fire safety law

The rule

Section 3(3A) of the Maharashtra Fire Prevention and Life Safety Measures Act, 2006, and the Amendment Rules notified on 12 June 2025, require an IoT-based ACMS for the fire-fighting system of buildings specified under section 45 of the Act.

Two phases

Phase I (immediate): real-time system status to the owner/occupier and the licensed agency. Phase II (later): critical alarms also sent to the local fire & emergency services through an API.

Forms A-1 & B-1

A Licensed Agency certifies that ACMS has been provided (Form A-1), and certifies maintenance with the help of ACMS twice a year, in January and July (Form B-1).

What we monitor

All 20 parameters required by the rules

Pumps & power

  • Main hydrant pump run status
  • Main sprinkler pump run status
  • Standby diesel / electric pump
  • Jockey pump
  • Booster pump
  • Power to main hydrant pump
  • Power to main sprinkler pump

Pressure & water

  • Hydrant riser low pressure
  • Sprinkler riser low pressure (below 5 bar)
  • Underground / aboveground fire tank level
  • Overhead tank low level
  • Diesel tank low level

Fire alarm & PA

  • Detection operation status
  • Control / repeater panel status
  • Control panel battery
  • Manual call point operation
  • Public address system status

Smoke control

  • Staircase pressurisation fans
  • Lift lobby / hoistway pressurisation fans
  • Basement supply & exhaust fans
How it works

From your pump room to your phone

Sensors

Pressure switches and transmitters, ultrasonic tank-level sensors, voltage sensors at the MCC, and potential-free contacts from the fire panel.

IoT gateway

Collects every signal, with UPS backup of up to 7 hours, a real-time clock and 10,000+ event logs.

Secure cloud

Data sent every minute over encrypted MQTTS (4G/5G, Ethernet or Wi-Fi), stored with at least 99% uptime.

Alerts & reports

SMS, email and app alerts in real time, plus data and alarm reports for audits and Form B-1.

Fire brigade (Phase II)

API-ready to send critical alarms to the local fire and emergency services when notified.

Built to the rule book

Technical requirements we design to

1 minData interval to the cloud
15 minNo-data SMS alarm
7 hrsGateway UPS backup
10,000+Event logs stored on the gateway
MQTTSEncrypted machine-to-machine protocol
99%Minimum platform uptime
SMS · Email · AppReal-time alerts
API-readyFor Phase II fire-brigade alerts
Packages

A complete package, not just a box of sensors

Basic & Standard

Small and mid-size commercial buildings and housing societies.

Advanced

High-rise towers, hospitals, hotels and malls with multiple pumps, risers and fans.

Industrial & Enterprise

Factories, warehouses, data centres and multi-building campuses.

Every package includes a site survey, devices, installation, integration with your existing pumps and panels, commissioning, the cloud monitoring subscription, Form A-1 / B-1 documentation through a Licensed Agency, and AMC. Price on request, based on your building.

Why UltraSafe

Monitoring is only as good as the system behind it

An IoT dashboard that reports a broken pump does not make the pump work. UltraSafe has installed and maintained fire hydrant, sprinkler, pump and fire alarm systems since 2010, with 50+ turnkey projects and 100+ organisations protected, and our team has hands-on experience installing IoT monitoring devices.

So we survey and fix your system first, then monitor it, then keep it maintained under one AMC, from our offices in Mumbai, Indore and Raipur, serving clients across India.

Our Mumbai Services
Fire hydrant pump room ready for IoT monitoring
FAQ

ACMS Questions

Is ACMS mandatory in Maharashtra?

Yes, for the buildings specified under section 45 of the Maharashtra Fire Prevention and Life Safety Measures Act, 2006. The Amendment Rules notified on 12 June 2025 require an IoT-based Automated Continuous Monitoring System for the fire-fighting system, with Phase I taking effect immediately.

What does an ACMS monitor?

The rules list 20 parameters, including the run status of the hydrant, sprinkler, standby, jockey and booster pumps; power to the main pumps; hydrant and sprinkler riser low pressure; fire water tank and diesel tank levels; fire alarm panel, battery, detection and manual call point status; PA system status; and pressurisation and basement exhaust fans.

What is the difference between Phase I and Phase II?

In Phase I, the system sends real-time status and alerts to the owner or occupier and to the licensed agency that installed it. In Phase II, which will be notified later, critical alarms such as pump power failure, low line pressure or fire-alarm faults will also be sent to the local fire and emergency services through an API.

Can ACMS be added to an existing, older hydrant system?

Yes. ACMS is a monitoring layer. Sensors are added to your existing pumps, risers, tanks and fire alarm panel, and connected to an IoT gateway. We first survey your system and fix anything that is not working, so that what the dashboard shows is real.

What happens if the internet or power goes off?

The rules require the gateway to have UPS backup of up to 7 hours, a real-time clock and storage for at least 10,000 event logs. The cloud portal must also raise an SMS alarm if no data is received from the gateway for more than 15 minutes.

What are Form A-1 and Form B-1?

Form A-1 is the certificate, issued by a Licensed Agency, that the automated continuous monitoring system has been provided. Form B-1 is issued by a Licensed Agency twice a year, in January and July, confirming that the fire-fighting systems are maintained in good repair with the help of the ACMS.

Who receives the alerts?

Building owners, facility managers or society office-bearers you nominate, plus the maintaining agency, by SMS, email and mobile app. Reports of data and alarms are available from the cloud portal at any time.

Do you also maintain the hydrant, sprinkler and alarm systems?

Yes. UltraSafe has installed and maintained hydrant, sprinkler, fire alarm and pump systems since 2010, so one team handles the systems, the monitoring and the AMC.

Reference: Maharashtra Fire Prevention and Life Safety Measures (Amendment) Rules, 2025 — Urban Development Department notification No. MFS-2023/C.R.370/UD-14 dated 12 June 2025. Read the full guide: ACMS rules explained.

Is your building ACMS-ready?

Book a free readiness check. We will survey your pumps, risers, tanks and alarm panel and tell you exactly what is needed.