Fire Alarm & Solar System

  • Palex 4 Zone Burglar Alarm Panel
    18450 20500

    PCW8ZA

    Availability: In stock

    • Operates on 220 V AC, 50 Hz AC Supply
    • 16*2 Line dot matrix LCD
    • Battery Backup with inbuilt charger
    • Operates on both tone and pulse
    • User password protection
    • Speech dialer with 06 telephone nos. and 01 message
    • 30 sec. duration time of message
    • Real Time clock with 128 events logging facility
    • LCD display Current date and time with current status of all zone
    • Automatic and manual operation facility for security zone
  • Key Fob
    1422 1580

    KF

    Availability: In stock

    • It can arm/disarm alarm host and make emergency alarm.
    • It adopts resonance when emit signal, so it is very stable .
  • Wireless Fire Alarm System
    11250 12500

    WFASE

    Availability: In stock

    With prosperous industry practice, we are known to offer Wireless Fire Alarm SystemIt is made by experts using the advanced technology.
  • 16 Zone Fire Alarm System
    4500 5000

    16ZFAS

    Availability: In stock

    Banking on the skills of our qualified team of professionals, we are involved in providing 16 Zone Fire Alarm System.
  • 4 Zone Fire Alarm Panel
    4680 5200

    4ZFAP

    Availability: In stock

    With an objective to fulfill the ever evolving demands of our clients, we are engaged in offering a wide assortment of 4 Zone Fire Alarm Panel.
  • Sounder Control Unit With Isolator
    3420 3800

    SCUWI

    Availability: In stock

    The Module is a interface which is used to connect a line of conventional sounders to the GFE’s range of Addressable Fire Detection Control Panels via the detection loop. The green LED will pulse every time the unit is polled by the panel. Three LEDS are provided to indicate module status. The Yellow LED will be ON whenever there is a fault condition in the module and finally the Red LED will be ON when there is an alarm condition in the conventional zone.
  • Fire Alarm Addressable Sounder
    3330 3700

    FAAS

    Availability: In stock

    Our firm has hold specialization in offering a variety of Alarm Sounder Beacon. This alarm sounder beacon is precisely integrated at vendors' end, utilizing the finest components and leading technology in the direction of professionals. The offered alarm sounder beacon is accredited in the industry for their fine performance. This alarm sounder beacon is examined by our quality inspectors for their specified features.
  • 20D Ioslating Bases
    1350 1500

    20DLB

    Availability: In stock

    The Context Plus XP95 20D isolating base senses and isolates short circuit faults on loops and spurs. The base is loop powered, polarity sensitive and accepts the XPERT card to set the associated device address. In short circuit conditions, the integral yellow LED is illuminated. The detector associated with the base remains active under short circuit conditions. Power and signals to the affected section are restored automatically when the fault is cleared. Under normal operating conditions, a low impedance is present between the ? IN and ? OUT terminals of the base, so that power and signals pass to the next base in the line. If a short circuit or abnormally low impedance occurs, the fall in voltage is sensed and the base isolates the negative supply in the direction of the fault.
  • Mounting Bases
    1260 1400

    MB

    Availability: In stock

  • Manual Call Points
    1080 1200

    MCP

    Availability: In stock

    So as to acquire utmost level of customer credibility and trust, we are  in delivering to our patrons a wide plethora of Manual Call Points.
  • Multisensor Detector
    1620 1800

    MSD

    Availability: In stock

    The Context Plus XP95 multisensor detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value. The multisensor construction is similar to that of the optical detector but uses a different lid and optical mouldings to accommodate the thermistor temperature sensor. The sectional view (below) shows the arrangement of the optical chamber and thermistor. The signals from the optical smoke sensing element and the temperature sensor are independent, and represent the smoke level and the air temperature respectively in the vicinity of the detector. The detector?s microcontroller processes the two signals. The temperature signal processing extracts only rate of rise information for combination with the optical signal. The detector will not respond to a slow temperature increase ? even if the temperature reaches a high level. A large sudden change in temperature can, however, cause an alarm without the presence of smoke, if sustained for 20 seconds.
  • Resistance Temperature Detector
    1035 1150

    RTD

    Availability: In stock

    Context Plus XP95 temperature (heat) detectors have a common profile with ionisation and optical smoke detectors but have a low air flow resistance case made of self-extinguishing white polycarbonate. They monitor temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. The response to temperature increases of the standard temperature detector (part no: 55000-400IMC) enables the detector to be utilized as an EN54 Grade 2 heat detector. To provide a device for use in ambient temperatures of up to 50?C, a high temperature detector (part no: 55000-401IMC) is also available. This has similar characteristics to the standard temperature detector at 25?C but reaches a 55 count (alarm) at 90?C.
  • Smoke Detector
    1125 1250

    SD

    Availability: In stock

    The Context Plus XP95 ionisation smoke detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Stainless steel wiper contacts connect the detector to the terminals in the mounting base. Inside the detector case is a printed circuit board that has the ionisation chamber mounted on one side and the address capture, signal processing and communications electronics on the other. The ionisation chamber system is an inner reference chamber contained inside an outer smoke chamber. The outer smoke chamber has smoke inlet apertures that are fitted with an insect resistant mesh. The radioactive source holder and the outer smoke chamber are the positive and negative electrodes respectively. An americium 241 radioactive source mounted within the inner reference chamber irradiates the air in both chambers to produce positive and negative ions. On applying a voltage across these electrodes an electric field is formed. The ions are attracted to the electrode of the opposite sign, some ions collide and recombine, but the net result is that a small electric current flows between the electrodes.
  • Addressable Fire Alarm Control Panel
    97200 108000

    AFAS

    Availability: In stock

    The Oriel series of Microprocessor based fire alarm panels are an upgraded version which provides a reliable and cost effective solutions to fire detection, from small to large size installations which have 2, 4, 6, 8 & could go up to 60 zones of selecting models and features. These units have been designed to offer high standards of performance, reliability and quality and comply with IS 2189 : 1999 and tested by the ERTL (N).The Oriel series panels are specially suited for the small offices, workplaces, small & high rise buildings.
  • XFP 1-2 Loop Networkable Analogue
    97200 108000

    LNA

    Availability: In stock

    XFP Networkable one loop 32 zone panel Agni Context Plus XP95 protocol. Code entry, c/w 3A psu, metal enclosure. XFP Networkable one loop 32 zone panel Agni Context Plus XP95 protocol. Keyswitch entry, c/w 3A psu, metal enclosure.
  • Sounders AD-502
    945 1050

    SAD

    Availability: In stock

    The Electronic sounder is designed for use within fire alarm systems, security systems and industrial signaling systems. Combined sounder and beacon provides an audio-visual warning which is suitable for place which requires high sound output and visual indication.
  • Heat Detector
    1035 1150

    HD

    Availability: In stock

    Agni AD-912 series detectors meet the requirements of UL 268 and EN 54-7/5 for use in Fire Alarm signaling systems. They are intended for use in 2-wire/4 wire Class A or B supervised zone circuits. The AD -912 Series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72E standards, local codes, and ordinances.
  • Optical Smoke Detector
    1035 1150

    OSD

    Availability: In stock

    AD-333 series include 2-wire and 4-wire detectors, which provide fast and reliable response to photoelectric smoke and heat (1350F) detection. While the smoke and heat detection circuits operate independently, their outputs being "OR" connected. The detector provide the fire detection performance by acting as a smoke sensor and / or a 1350F heat detector at the same location.
  • Optical Smoke Cum Heat Detector
    1395 1550

    OSHD

    Availability: In stock

    All of Agni AD333 series detectors meet the requirements of UL 268 and EN 54-7/5 for use in Fire Alarm signaling systems. They are intended for use in 2-wire/4 wire Class A or B supervised zone circuits. The AD 333 Series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 72E standards, local codes, and ordinances.
  • Remote Indicating Lamp AD-301 MW
    99 110

    RIL

    Availability: In stock

    The unit is designed to ensure that Alarm Signal can be actually transmitted to all locations. To prevent any missing signal specially for the close room.
  • Remote Indicating Lamp AD-301
    108 120

    RILAD

    Availability: In stock

    The unit is designed to ensure that Alarm Signal can be actually transmitted to all locations. To prevent any missing signal specially for the close room.
  • Sounders (ADESF1)
    2295 2550

    SADESF

    Availability: In stock

    The Electronic sounder is designed for use within fire alarm systems, security systems and industrial signaling systems. Combined sounder and beacon provides an audio-visual warning which is suitable for place which requires high sound output and visual indication.
  • Manual Call Points AD-101
    945 1050

    MCP

    Availability: In stock

    The Manual Call Point is tough, durable & highly visible.A Alarm LED/s is provided inside the Call Point to indicate the Alarm condition.
Scroll